1. Heating cables feature a joint connecting the "cold" (non-heating) and "hot" (heating) sections. Whether this connection is made via welding or crimping, it must remain reliable over the long term, even when exposed to high temperatures, oxidation, or corrosion. Excessive power (or excessive current) at this joint may create a risk of overcurrent.

 

2. Given that a 220V AC supply may experience voltage fluctuations of up to 10%, and accounting for factors such as the aging of electrical wiring, technical variances in electrical equipment and heating elements, and the current ratings of thermostats, the maximum power capacity of a thermostat should be at least 20% greater than the power rating of the heating element.

 

3. For heating elements with a power rating of up to 2816W, a thermostat with a 16A current capacity may be used. For heating elements with a power rating between 2816W and 3520W, a thermostat with a 20A current capacity should be selected.